testo 310 - Flue Gas Analyser (Standard Kit)

SKU: 5633100

Price:
Sale price£457.16 inc VAT

Description

      • Simultaneous measurement of O2, CO, and flue gas and ambient temperatures

      • Measurement menus for flue gas, draught, CO environment and pressure

      • Sensor zeroing in 30 seconds

      • Rechargeable lithium battery for up to 10 hours of operation

      • Reading printout with portable printer

      • Robust construction

      Being a systems mechanic you know only too well how tough things can get when you’re working out in the field. That’s why your measuring tools need to be rugged and reliable. Like the testo 310 flue gas analyzer. Designed especially for use in the field.

  • Details

    Product Description

    Overview

    The Testo 310 Flue Gas Analyser combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems. Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the testo 310 a robust tool for daily work – even when things get rough.

    With its capability to perform both basic or more complex combustion analysis, perform maintenance or safety checks, or confirm boiler efficiency, the fully featured testo 310 residential combustion analyser is ready to provide accurate analysis. The stainless steel probe and cone-stop is perfect for residential, and boiler efficiency applications. Simple top-of-display icons show you the current measurement functions. After only 30 seconds, the 310 is ready to test. With five different fuels to select from (Natural Gas, Propane, Fuel Oil 2, Biomass 5%, Wood 20%), it provides the flexibility you need for all your residential combustion analysis applications.

    Measures:

    • O2, CO (with built-in NOx filter), CO2
    • Undiluted CO (CO air free)
    • Ambient CO
    • Draft & Pressure
    • Temperature (flue & ambient)
    • Combustion/flue gas efficiency & excess air

    Delivery Scope

    testo 310 - Flue Gas Analyser, Hard case, rechargeable battery, usb mains cable, silicon hose for pressure, 5 x filters, calibration protocol, 180mm probe with cone, spare pressure plugs.



    Technical Data

    General technical data

    Weight

    (with probe) Approx. 700 g

    Dimensions

    201 x 83 x 44 mm

    Operating temperature

    -5 to +45 °C

    Display type

    LCD (Liquid Crystal Display)

    Display function

    Backlit 2-line display

    Power supply

    Battery: 1500 mAh, mains unit 5V/1A

    Storage temperature

    -20 to +50 °C

    Temperature - TC Type K (NiCr-Ni)

    Measuring range

    -20 to +100 °C

    Accuracy

    ±1 °C

    Resolution

    0.1 °C

    Reaction time

    < 50 s

    Temperature (ambient temperature)

    Temperature - TC Type J (Fe-CuNi)

    Measuring range

    0 to +400 °C

    Accuracy

    ±1 °C (0 to +100 °C)

    ±1.5 % of mv (> 100 °C)

    Resolution

    0.1 °C

    Reaction time

    < 50 s

    Temperature (flue gas)

    Flue gas O₂

    Measuring range

    0 to 21 Vol.%

    Accuracy

    ±0.2 Vol.%

    Resolution

    0.1 Vol.%

    Reaction time t₉₀

    30 s

    Differential Pressure flue gas Draught - Piezoresistive

    Measuring range

    -20 to +20 hPa

    Accuracy

    ±0.03 hPa (-3.00 to +3.00 hPa)

    ±1.5 % of mv (Remaining Range)

    Resolution

    0.01 hPa

    Flue gas degree of effectivity, Eta (calculated)

    Measuring range

    0 to 120 %

    Resolution

    0.1 %

    Flue gas loss (calculated)

    Measuring range

    0 to 99.9 %

    Resolution

    0.1 %

    Flue gas CO₂ calculation (calculated from O₂)

    Measuring range

    0 to CO₂ max (Display range)

    Accuracy

    ±0.2 Vol.%

    Resolution

    0.1 Vol.%

    Reaction time t₉₀

    < 40 s

    Pressure measurement

    Measuring range

    -40 to +40 hPa

    Accuracy

    ±0.5 hPa

    Resolution

    0.1 hPa

    Flue gas CO (without H₂-compensation)

    Measuring range

    0 to 4000 ppm

    Accuracy

    ±20 ppm (0 to 400 ppm)

    ±5 % of mv (401 to 2000 ppm)

    ±10 % of mv (2001 to 4000 ppm)

    Resolution

    1 ppm

    Reaction time t₉₀

    60 s

    Ambient CO

    Measuring range

    0 to 4000 ppm

    Accuracy

    ±20 ppm (0 to 400 ppm)

    ±5 % of mv (401 to 2000 ppm)

    ±10 % of mv (2001 to 4000 ppm)

    Resolution

    1 ppm

    Reaction time

    60 s

BrandTESTO (CAT 100)

You may also like

Recently viewed